New Module a good performer. It's doing about 105 MeV.
 
New Module a good performer. It's doing about 105 MeV.
 
Cavity two had vacuum issues solved by setting to 19.5 MeV.
 
Cavity two had vacuum issues solved by setting to 19.5 MeV.
Best cryomodule in the machine now.
+
Best cryomodule in the machine now. Cavity Eight had
 +
a low onset of FE, running at 12.5 MeV; running now without FE.
 +
 
  
 
2. Waveform Faults Waveforms (Powers)
 
2. Waveform Faults Waveforms (Powers)

Latest revision as of 14:36, 27 January 2020

Attendance

K. Baggett, J. Benesch, M. Bickley, E. Daly, K. Davis, M. Drury, C. Hovater, R. Geng, C. Ginsburg, K. Jordan, A. Kimber, L. King, G. Krafft, F. Marhauser, R. Michaud, C. Mounts, R. Nelson, W. Oren, A. Palczewski., T. Plawski, T. Powers, J. Preble, T. Reilly, A. Seryi, S. Suhring, M. Spata, and H. Wang

Agenda and Notes

1. Operations Status and Summary/Review (Bickley)

New Module a good performer. It's doing about 105 MeV. Cavity two had vacuum issues solved by setting to 19.5 MeV. Best cryomodule in the machine now. Cavity Eight had a low onset of FE, running at 12.5 MeV; running now without FE.


2. Waveform Faults Waveforms (Powers)

CEBAF Vacuum: "Cold" Vacuum System and Interlocks

Linac Vacuum Section: CEBAF Design Handbook

CEBAF Vacuum System and Interlocks for Original 4 GeV Accelerator

Beam Pipe and Waveguide Vacuum Interlocks (Author: K. Jordan)

WBS1 VACUUM CONTROL SYSTEM (Author: K. Jordan)

CEBAF C100 Style Vacuum Interlocks


3. Cavity Gradient Degradation (Benesch)

Cavity Gradient Degradation

RF Dashboard


4. Vacuum Trip Thresholds for Various Sites (Geng)

Beamline Vacuum Trip Thresholds for Various Accelerators