PITMinutes 03-11-2019

From CASA Wiki
Revision as of 13:21, 11 March 2019 by Krafft (Talk | contribs) (Agenda and Notes)

Jump to: navigation, search

Attendance

R. Bachimanchi, K. Baggett, A. Freyberger, R. Geng, C. Hotaver, G. Krafft, A. Kimber, R. Legg, C. Mounts, R. Nelson, T. Plawski, T. Powers, C. Reece, S. Suhring, and H. Wang.

Agenda and Notes

1. Operations Status and Summary/Review (Freyberger)

Notble event during OPS last week. Net result is gradients in two modules turned back to below onset of FE. Question to be discussed is whether all should get similar treatment.


Pre-cursors


Mount/Pwers observed many quench faults in 1L25-8 that are not quenches but are ????

1L25 and 1L26 themal cycled to 30 K in Jan. Modest Help?


Event Description

Vaccum degrades

1L25-8 becomes Unstable

valve fails

1L25-8 by-passed not recoverable

gradient loss in 1L25-7


Recovery

Neutron detectors used to find new 1L25 and 1L26 gradients

20+ MeV energy loss in 1L25

8 MeV energy loss in 1L26

Warm region vacuumn almost back to nominal


Scaled back to 1020 in the NLINAC


2. Cryomodule Shuffle ????

2. Plasma Cleaning (Powers)

Funding approved

Action Items

Leadership of quenches. Offline discussion.

C100 Refurbishment Project for the future?