Difference between revisions of "AP-CEBAF-Optics-2015-02-28"
Line 87: | Line 87: | ||
# ~satogata/tools/analyzeZigZagRange.pl IHA1E03.SA.02282015_00:28:42 | # ~satogata/tools/analyzeZigZagRange.pl IHA1E03.SA.02282015_00:28:42 | ||
This tool prints out the quadrupole that is being scanned, the list of scans and corresponding BDL and K values for that quad, and uses gnuplot to plot the zigzag scan data. One can then count the peaks and look up the corresponding BDL and K values for use in qsUtility configuration files. | This tool prints out the quadrupole that is being scanned, the list of scans and corresponding BDL and K values for that quad, and uses gnuplot to plot the zigzag scan data. One can then count the peaks and look up the corresponding BDL and K values for use in qsUtility configuration files. | ||
+ | |||
+ | '''zigzag2qsUtility''': Dennis has a tool that converts zigzag scans to input files for qsUtility, though at present the qsUtility file that is generated needs to have the quadrupole K values added manually. An example for IHA3E01 is | ||
+ | # zigzag2qsUtility -scan_file=IHA3E01.SA.03032015_10:48:30 -show_plots -exclusion_zone=0.15 -plane=X -lattice_name=test -momentum=2200 -start_element=MQA3S10 -pass=2 |
Revision as of 19:35, 3 March 2015
This is a wiki page for references, information, and procedures about Feb 27-Mar 1 work to transversely match CEBAF Twiss parameters at the injector (~0L07), 1E03, and xE01 locations.
Contents
Philosophy
The philosophy was developed at a 15:00 meeting in MCC, including Arne Freyberger, Mike Spata, Yves Roblin, Mike TIefenback, Jay Benesch, Todd Satogata, and Operations:
- use zigzag harp scans to identify quadrupole ranges for good optics/emittance measurements at each harp.
- modify qsUtility configuration files in the golden area and acquire optics/emittance measurements with traditional qsUtility scans.
- use qsUtility to analyze the scans and get measured horizontal/vertical Twiss parameters at the start of the respective scan quads.
- back-propagate measured Twiss parameters to the start of the upstream xS04 quadrupole.
- use the qsUtility betatron match module (which uses ced2elegant and elegant) to calculate the match, with match point at the harp, using xS04-xS10 quadrupoles for matching to distribute matching effort.
- evaluate and install the match.
- re-scan the harp and compare beam sizes to sqrt(emit_meas * beta_design)
Prerequisites at Each Measurement Location
- 4-8 uA tune beam to first dumplette downstream of match point.
- quad centering of BPM/quadrupole pairs for qsUtility scan quadrupoles.
- clean steering in region of measurement and downstream to maximize aperture, minimize beam losses.
- clean ORFP dispersion in region of measurement and correction. In particular, dispersion in both planes must be consistent with zero at scan quadrupoles and harp.
Procedure
- confirm harp is working and set harp parameters
- perform zigzag measurements to establish scan quadrupoles and ranges
- edit qsUtility configuration files if necessary
- configuration files are in /a/opsdata/fiefdata/fileio/q/qsUtility/config/F3-0/GoldenTemplates
- perform qsUtility scans
- evaluate qsUtility data to get measured Twiss parameters and emittances
- back-propagate measured Twiss parameters to start of upstream xS04 quadrupole with elegant
- A script to do this is in ~satogata/backpropagate.pl
- use qsUtility betatron match module to calculate xS04-xS10 match
- configuration files are in /a/opsdata/fiefdata/fileio/q/qsUtility/match_config/F3-0
- evaluate and install match
- re-scan harp and evaluate match effectiveness
- After match is installed, one has to set the recombiner quads back to design in order to proceed to the next arc.
- perform confirmation fopt
Data and References
- Spring 2015 Optics Spreadsheet (Google docs)
- 0L injector match (E=107.2 MeV, BDL=536.365*K1 for L=0.15m magnets)
- 0L07 H: zigzags -> MQD0L06 horizontal scan centered near 1800G, range +/-270G (BDL 3.35+/-0.5)
- 0L08 V: zigzags -> MQB0L07 vertical scan centered near -3600G, range +/-500G (BDL -6.71+/-1.0)
- Match calculation results and loading: e3322599 using C-laser, IHA0L07_2015-02-28_23:26 and IHA0L07_2015-03-01_00:01 datasets.
- 1E03 match (E=1057.2 MeV, BDL=5289.659*K1 for L=0.15m magnets, be careful MQN1S04 is L=0.30m, others are L=0.15m):
- 2E01 match (E=2007.2 MeV, BDL=20085.89*K1 for L=0.30m magnets):
- 2E01 H: zigzags zigzags-> MQC2S10 horizontal scan centered near 4600G, range +/-1000G (BDL 0.229+/-0.05)
- 2E01 V: No zigzag solution found. Todd explored space with qsUtilityConfig and found reasonable scan of MQC2S08 K=-0.6 to 0.6 with MQC2S09 K=-0.1 m^-2 and MQC2S10 K=0.2 m^-2 (image)
- In order to test that with the zigzag do the following (yves):
# caput MQC2S09.BDL -2009 # caput MQC2S10.BDL 4017 # scan_script.csh run IHA2E01 MQC2S08 Y 12051.000 -12051.000 9
then restore the 2S09 and 2S10 quads .
- 2E01 horizontal scan and analysis
- 2E01 vertical scan and analysis
- 2E01 backpropagation and fitting
- 3E01 match (E=2957.2 MeV, BDL=29592.47*K1 for L=0.30m magnets):
- 3E01 H: broad scan IHA3E01_2015-02-23_22:27.sdds of MQA3S10 with MQB3E01=-0.7991 shows minimum near K1=1.1 m^-2, decent range K1=1.6 to 0.6. Put into IHA3E01-x-GOLD.xml.
- 3E01 V: broad scan IHA3E01_2015-02-23_22:27.sdds of MQA3S10 with MQB3E01=-0.7991 shows minimum near K1=1.35 m^-2, decent range K1=2.1 to 0.65. Put into IHA3E01-y-GOLD.xml.
- 3E01 horizontal zigzag analysis and vertical zigzag analysis and match calculation
- 3E01 fopt after 3E match and viewer walk, all looking good
- 4E01 match (E=3907.2 MeV, BDL=39099.05*K1 for L=0.30m magnets):
- The 02242015 4E01 scans indicate a need for vertical quad centering at MQA4S09. (done Mar 3 2015 13:30)
- 4E01 H: broad scan IHA4E01_2015-02-24_00:38.sdds of MQA4S09 with MQA4S10=0.2538 and MQB4E01=-0.5713 shows minimum near K1=0.0 m^-2, decent range K1=0.5 to -0.5. Profiles look ratty.
- 4E01 V: broad scan IHA4E01_2015-02-24_00:38.sdds of MQA4S09 with MQA4S10=0.2538 and MQB4E01=-0.5713 shows minimum near K1=-0.45 m^-2, decent range K1=0.9 to -1.8.
- 4E01 horizontal zigzag analysis and vertical zigzag analysis and corrected match calculation
- 4E01 fopt after 4E match and viewer walk, all looking good
- 5E01 match (E=4857.2 MeV, BDL=48605.63*K1 for L=0.30m magnets):
- Initial zigzag scans with design ranges indicated a need for quad centering.
- IHA5E01 harp appears broken: e3323035
- 6E01 match (E=5807.2 MeV, BDL=58112.20*K1 for L=0.30m magnets):
- 8E01 match (E=7707.2 MeV, BDL=77125.36*K1 for L=0.30m magnets):
- 9E01 match (E=8657.2 MeV, BDL=86631.93*K1 for L=0.30m magnets):
- AE01 match (E=9607.2 MeV, BDL=96138.51*K1 for L=0.30m magnets):
- 5C00 match (E=10557.2 MeV, BDL=105645.09*K1 for L=0.30m magnets):
- 1C match (E=9607.2 MeV, fifth pass, BDL=96138.51*K1 for L=0.30m magnets):
- 2C match (E=2007.2 MeV, first pass, BDL=20085.89*K1 for L=0.30m magnets):
- rayTrace data: 3322485 H 3322488 H 3322490 V
Useful Tools
setquadstomachine: During the backpropagation or the matching calculation, if one wants to take into account quadrupoles that are off design, one can use the script ~roblin/tools/setquadstomachine which together with a snap file of the region in question produces a sdds file suitable for inclusion in the ELEGANT command file via load_parameters. usage is
# ~roblin/tools/setquadstomachine <commandfile> <snapfile>
and it will make QUADparams.sdds ready for load_parameters. Read the comments in the script for further details (or page Yves).
analyzeZigZagRange.pl: Todd has written a tool to help analyze zigzag scans for quad scan ranges. Usage is, for example,
# ~satogata/tools/analyzeZigZagRange.pl IHA1E03.SA.02282015_00:28:42
This tool prints out the quadrupole that is being scanned, the list of scans and corresponding BDL and K values for that quad, and uses gnuplot to plot the zigzag scan data. One can then count the peaks and look up the corresponding BDL and K values for use in qsUtility configuration files.
zigzag2qsUtility: Dennis has a tool that converts zigzag scans to input files for qsUtility, though at present the qsUtility file that is generated needs to have the quadrupole K values added manually. An example for IHA3E01 is
- zigzag2qsUtility -scan_file=IHA3E01.SA.03032015_10:48:30 -show_plots -exclusion_zone=0.15 -plane=X -lattice_name=test -momentum=2200 -start_element=MQA3S10 -pass=2