Difference between revisions of "PITMinutes 02-24-2020"

From CASA Wiki
Jump to: navigation, search
(Agenda and Notes)
(Agenda and Notes)
 
Line 7: Line 7:
  
 
1. Operations Status and Summary/Review (Bickley)
 
1. Operations Status and Summary/Review (Bickley)
 
New Module a good performer. It's doing about 105 MeV.
 
Cavity two had vacuum issues solved by setting to 19.5 MeV.
 
Best cryomodule in the machine now. Cavity Eight had
 
a low onset of FE, running at 12.5 MeV; running now without FE.
 
  
  

Latest revision as of 14:22, 24 February 2020

Attendance

K. Baggett, J. Benesch, M. Bickley, E. Daly, K. Davis, M. Drury, C. Hovater, R. Geng, C. Ginsburg, K. Jordan, A. Kimber, L. King, G. Krafft, F. Marhauser, R. Michaud, C. Mounts, R. Nelson, W. Oren, A. Palczewski., T. Plawski, T. Powers, J. Preble, T. Reilly, A. Seryi, S. Suhring, M. Spata, and H. Wang

Agenda and Notes

1. Operations Status and Summary/Review (Bickley)


2. Waveform Faults Update (Powers)

Waveform Faults Update


3. Particulate Monitor (Geng)

Beamline Vacuum Trip Thresholds for Various Accelerators