Difference between revisions of "PITMinutes 03-11-2019"

From CASA Wiki
Jump to: navigation, search
(Attendance)
(Attendance)
Line 1: Line 1:
 
== Attendance ==
 
== Attendance ==
  
A. Freyberger, R. Geng, C. Hotaver, G. Krafft, A. Kimber, R. Legg, F. Marhauser, R. Michaud, R. Nelson, T. Plawski, T. Powers, B. Rimmer, C. Reece, A. Solopova, and H. Wang.
+
A. Freyberger, R. Geng, C. Hotaver, G. Krafft, A. Kimber, R. Legg, F. Marhauser, R. Michaud, R. Nelson, T. Plawski, T. Powers, B. Rimmer, C. Reece, T. Reilly, A. Solopova, and H. Wang.
  
 
== Agenda and Notes ==
 
== Agenda and Notes ==

Revision as of 14:28, 11 March 2019

Attendance

A. Freyberger, R. Geng, C. Hotaver, G. Krafft, A. Kimber, R. Legg, F. Marhauser, R. Michaud, R. Nelson, T. Plawski, T. Powers, B. Rimmer, C. Reece, T. Reilly, A. Solopova, and H. Wang.

Agenda and Notes

1. Operations Status and Summary/Review (Freyberger)

Notble event during OPS last week. Net result is gradients in two modules turned back to below onset of FE. Question to be discussed is whether all should get similar treatment? More n detectors ordered. Do measurements during the summer?


Pre-cursors


Mount/Pwers observed many quench faults in 1L25-8 that are not quenches but are ????

1L25 and 1L26 thermal cycled to 30 K in Jan. Modest Help?


Event Description

Vaccum degrades

1L25-8 becomes Unstable

valve fails

1L25-8 by-passed not recoverable

gradient loss in 1L25-7


Recovery

Neutron detectors used to find new 1L25 and 1L26 gradients

20+ MeV energy loss in 1L25

8 MeV energy loss in 1L26

Warm region vacuun almost back to nominal


Scaled back to 1000 in the NLINAC, 1020 in the SLINAC

New neutron detectors below both 1L25 and 1L26 Tune gradient to no neutrons detected.


2. Cryomodule Shuffle ????

3. Plasma Cleaning (Powers)

Funding approved

Action Items

Leadership of quenches. Offline discussion.

C100 Refurbishment Project for the future?