Difference between revisions of "PITMinutes 03-11-2019"
(→Agenda and Notes) |
(→Agenda and Notes) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Attendance == | == Attendance == | ||
− | + | A. Freyberger, R. Geng, C. Hotaver, G. Krafft, A. Kimber, R. Legg, F. Marhauser, R. Michaud, R. Nelson, T. Plawski, T. Powers, B. Rimmer, C. Reece, T. Reilly, A. Solopova, and H. Wang. | |
== Agenda and Notes == | == Agenda and Notes == | ||
Line 7: | Line 7: | ||
1. Operations Status and Summary/Review (Freyberger) | 1. Operations Status and Summary/Review (Freyberger) | ||
− | + | Notable event during OPS last week. Net result is gradients in two modules | |
turned back to below onset of FE. Question to be discussed is whether | turned back to below onset of FE. Question to be discussed is whether | ||
− | all should get similar treatment? More | + | all should get similar treatment? More neutron detectors ordered. |
Do measurements during the summer? | Do measurements during the summer? | ||
− | |||
Line 17: | Line 16: | ||
− | + | Mounts/Powers observed many quench faults in 1L25-8 that are not quenches but are ???? | |
1L25 and 1L26 thermal cycled to 30 K in Jan. Modest Help? | 1L25 and 1L26 thermal cycled to 30 K in Jan. Modest Help? | ||
Line 43: | Line 42: | ||
8 MeV energy loss in 1L26 | 8 MeV energy loss in 1L26 | ||
− | Warm region | + | Warm region vacuum almost back to nominal |
Line 50: | Line 49: | ||
1020 in the SLINAC | 1020 in the SLINAC | ||
− | New neutron detectors below both 1L25 and 1L26 | + | New neutron detectors placed below both 1L25 and 1L26 |
Tune gradient to no neutrons detected. | Tune gradient to no neutrons detected. | ||
Latest revision as of 16:41, 25 March 2019
Attendance
A. Freyberger, R. Geng, C. Hotaver, G. Krafft, A. Kimber, R. Legg, F. Marhauser, R. Michaud, R. Nelson, T. Plawski, T. Powers, B. Rimmer, C. Reece, T. Reilly, A. Solopova, and H. Wang.
Agenda and Notes
1. Operations Status and Summary/Review (Freyberger)
Notable event during OPS last week. Net result is gradients in two modules turned back to below onset of FE. Question to be discussed is whether all should get similar treatment? More neutron detectors ordered. Do measurements during the summer?
Pre-cursors
Mounts/Powers observed many quench faults in 1L25-8 that are not quenches but are ????
1L25 and 1L26 thermal cycled to 30 K in Jan. Modest Help?
Event Description
Vaccum degrades
1L25-8 becomes Unstable
valve fails
1L25-8 by-passed not recoverable
gradient loss in 1L25-7
Recovery
Neutron detectors used to find new 1L25 and 1L26 gradients
20+ MeV energy loss in 1L25
8 MeV energy loss in 1L26
Warm region vacuum almost back to nominal
Scaled back to 1000 in the NLINAC, 1020 in the SLINAC
New neutron detectors placed below both 1L25 and 1L26 Tune gradient to no neutrons detected.
2. Cryomodule Shuffle ????
3. Plasma Cleaning (Powers)
Funding approved
Action Items
Leadership of quenches. Offline discussion.
C100 Refurbishment Project for the future?